35
Page 32
CLEANING - ICEMAKER
1. Empty bin of ice.
2. Remove front panel.
3. Wait till the end of the harvest cycle, switch
off the machine, then switch ON again, push
the CLEAN BUTTON on LED display for 2-3
seconds in one minute. The machine should go
to clean/sanitize procedure, and the red
CLEAN LED light on LED display will be fast
blinking in whole procedure.
4. In beginning 30” of clean procedure, machine
will purge water from sump, then pour on
- SVD 152…………………….185cc
- SVD 222……………..………210cc
- SVD 203-303………………..250 cc
- SVD 503……………………. 350 cc
of Simag Ice Machine Cleaner directly into the
reservoir while the water inlet valve will be
energized till the fill up of the water sump. The
water pump starts to operate.
5. After 10 minutes, machine will purge the
clean Cleaner solution, and refill up the water
sump, then go into automatic rinsing mode.
6. At the end of the 10th Rinsing cycle,
according DIP switch #9 setup, the machine:
#9 OFF
machine stops the operation and
blinking (slow) of the red Clean
LED.
Push the CLEAN BUTTON when
machine stop, the machine
restarts in the freezing cycle
#9 ON
Machine will go to freezing cycle
directly.
7. Replace the evaporator cover deflector and
front panel.
8. Check the next batch of cubes to be sure all
the cleaner is gone (no sour taste).
9. Pour hot water into the storage bin melt the
cubes, and to also clean the bin drain.
WARNING - Ice Machine Cleaner
contains
Phosphoric
and
Hydroxyacetic
acids.
These
compounds are
corrosive and may
cause burns. If swallowed, DO NOT
induce
vomiting.
Give
large
amounts of water or milk. Call
physician immediately. In case of
external contact, flush w
ith water.
KEEP OUT OF THE REACH OF
CHILDREN.
NOTE:
RINSING mode consists of:
a) Energize the water pump for 30”.
b) Energize the water drain valve and the
water pump for 30”.
c) Energize the
water inlet valve till the fill
upof the water sump.
The above sequence is repeated 10 times
so tobe sure to have removed any possi
ble
trace of Ice Machine Cleaner.
CAUTION
:
DO NOT use ice cubes produced
from the cleaning solution. Be
sure none remains in the bin.