FOR THE PLUMBER
CONFORM TO ALL APPLICABLE CODES
WATER INLET
AIR-COOLED MODELS
: The recommended
water supply is cold water connected to the -
3/4'’ gas - male fitting at the back of the cabinet.
Install a hand valve near the machine to control
the water supply.
1) Plug receptacle
2) Electrical plug
3) Water inlet
4) Shut-off valve
5) Water filter
6) Water inlet line
7) Water outlet line
8) Bin water outlet line
9) Open vented water drain
When choosing the water supply for the SVD
Cuber, consideration should be given to:
A. Length of run.
B. Water clarity and purity.
C. Adequate water supply pressures.
Since water is the most important single
ingredient in producing ice you cannot over
emphasize the three items listed above. Low
water pressure, below 1 bar may cause
malfunction, of the icemaker unit. Water
containing excessive minerals will tend to
produce cloudy colored ice cubes, plus scale
build-up on parts in the water system.
Heavily chlorinated water can be controlled
using charcoal or carbon filters.
DRAINS
AIR-COOLED MODELS
: There is one 20 mm.
diameter sump drain fitting at the back of the
cabinet. Insulations in high humidity areas is
recommended. The ideal drain receptacle
would be a trapped and vented floor drain.
STORAGE BIN
: A separate gravity type drain
needs to be run, similar to the air-cooled sump
drain. Insulation of this drain line is
recommended.