Operation  

 

 

12 

 

Folding and Unfolding the Devil Boom 

 
Unfolding

The  boom  will  slide  free  from  the 

saddles when unfolded. Use the tractor hydraulic 
lever to slowly unfold one arm at a time until the 
hydraulic cylinder is fully extended.  

  

Folding:  

Fold the boom slowly, one arm at a 

time with the tractor hydraulics until the arm 
rests on the support saddle.  

  

Devil Boom Setup 

1.Unfold each arm using the tractor remotes. 
2.When the hydraulic ram is fully extended, the 

bolt through the end of the ram must go the 
whole way to the end of the slot (below). Even 
a small gap will result in a whipping outer 
section. 

 

3.When the ram is at the end of the slot, the 

spring washers on the boom side of the 
bracket (right side below) must be fully 
compressed. 

 

4.After the ram setup is complete, make sure the 

outer arm pushrod is extended out so it holds 
the outer section down when the ram is at full 
stroke (if the push rod is set too short, the 
outer section will whip). 

  

Foam Marker 

Refer to the Foam Marker Operator’s Manual for 
installation and operating procedures relevant to 
the foam marker. 
 

Spray Guns and Hose Reels 

To operate the spray gun prime the pump as per 
normal then open the relevant control lever, set 
to the desired pressure (max 20 Bar). Depress 
the trigger to spray.  

 
 

 

 

 
 
 

 
 
 
 
 
 
 
Filling the Main Tank using Bottom 
Connection (1100L only) 

The main tank can be filled through either the 
top lid or bottom cam lock connection. The 
bottom cam lock is preferred as it stops the 
chemicals frothing. It is also safer as the tank 
can be filled from ground level. The bottom fill is 
protected from back flow by a non-return valve 
inside the tank. 
 
Undo the catches and remove the cap from the 
bottom fill connection. Connect a filling hose with 
a 50mm cam lock coupling to the connection 

Always ensure that the boom is folded or 
unfolded in a safe area where it will not foul 
on any other objects. Look up before folding or 
unfolding to check for obstructions. Never fold 
or unfold near overhead power lines. Ensure 
that all bystanders are clear before moving the 
boom. 

Correct Setup 

Incorrect Setup 

Ram Slot 

Summary of Contents for Super 1100L Series

Page 1: ...Operators Manual MANLINK 4D REV H 12 11 20 400L 600L 800 1100L Super Series Linkage Sprayer...

Page 2: ...nd safety and incorporate many innovative features To ensure continued efficient performance and safe operation of your sprayer you need to read this manual thoroughly and fully familiarise yourself w...

Page 3: ...om Attachment 11 Fresh water Tank Toolbox Spray Booms 11 Spray Guns Hose Reels and Foam Marker 12 Starting the sprayer 13 Chemical induction probe 1100L only 13 Shutdown 13 General Spraying Informatio...

Page 4: ...This Warranty is in addition to any other rights and remedies available to consumers under the law This Warranty Covers Only conditions resulting directly from defects in workmanship or material under...

Page 5: ...me care when operating in hilly or uneven terrain to ensure adequate stability Refer also to the tractor manufacturer s operating and safety instructions Do not operate the pump at speeds greater than...

Page 6: ...Decal Positions 6 DEC232 INS142 INSTRUCTION BOOKLET DEC52 DEC101213P DEC101213P US4 DEC232 DEC52 BOTH SIDES DEC07 INS142 US4...

Page 7: ...other salty concentrations Water with a temperature above 40 C and less than 5 C Any type of varnish Solvents and thinners for any type of varnish Any type of fuel or lubricant Liquids containing gra...

Page 8: ...er single side 16 litre foam marker double side electric 57 litre foam marker double side electric Spray Booms Field Boom 6m 8m or 10m Galvanized steel truss Three section horizontal fold Spring loade...

Page 9: ...eference Set the linkage height so that the ends of the two shafts are at their closest distance Install the PTO shaft making sure that there is at least 25mm of telescopic travel remaining between th...

Page 10: ...ON To Clean The Filter 1 Disengage the PTO 2 Turn the ball valve to the Off position 3 o clock 3 Unscrew the Filter Nut Remove the Filter Bowl 4 Clean the Filter 5 Secure the filter Filter Bowl in po...

Page 11: ...closing the lid Spray Booms A variety of booms may be used with Silvan linkage sprayers depending upon the model and field application All have stainless steel spray lines fitted with non drip nozzle...

Page 12: ...will whip Foam Marker Refer to the Foam Marker Operator s Manual for installation and operating procedures relevant to the foam marker Spray Guns and Hose Reels To operate the spray gun prime the pump...

Page 13: ...ion rate and other factors refer to the Calibration section of this manual Open the outlet valves that are connected to the boom or other spraying device to start spraying Under most boom spraying con...

Page 14: ...00 increases droplet size For an equivalent pressure and fan angle a larger size jet produces larger droplets Nozzle Height and Spacing To achieve a uniform spray pattern without gaps the output from...

Page 15: ...ction Chart on the following pages for the particular type and size fitted If the volume collected is too low the operating pressure may be increased and the test repeated alternatively if the volume...

Page 16: ...mple of how to use the calibration chart is shown below Using the Calibration Charts For example a rate of 96 l ha can be achieved at a ground speed of 10 kmh using 3 0 Bar pressure with a 110 02 yell...

Page 17: ...ype oil b If this happens after many hours of operation and continues after 1 or 2 top ups it is a symptom of diaphragm swelling caused by restricted suction dirty filter collapsed suction hose or che...

Page 18: ...ck for entry of air caused by entry of air caused by hose wear loose fittings worn joints 2 There are no small leaks or drips on the suction side of the pump when it is stationary If this occurs it me...

Page 19: ...e regulator valve and seats worn Pressure gauge faulty Pump diaphragms ruptured pump oil grey or milky Worn nozzles or capacity of nozzles greater than capacity of the pump Worn pump inlet outlet valv...

Page 20: ...1 144 AUSTRALIA HEAD OFFICE 68 Atlantic Drive Keysborough Victoria 3173 Telephone 1300 745 826 Fax 1800 745 826 www silvan com au NEW ZEALAND 22 Sunshine Ave Te Rapa Hamilton 3241 Telephone 0508 745 8...

Reviews: