background image

 

Safety Information  

 

 

 

 

Before operating the sprayer, read the following safety instructions. 

  

Failure to comply with these warnings may result in serious injury or death. 

 

 

 

 

 

This 

sprayer 

is 

designed 

and 

manufactured  solely  for  the  purpose  of 
applying agricultural chemicals to crops. 
Under  no  circumstances  should  it  be 
used for any other purpose. 

 

 

Before  using  the  sprayer,  carefully  read 
and ensure you understand the contents 
of  this  manual  and  any  other  manual 
supplied with the sprayer.    

 

 

Before operating the sprayer, read all the 
safety  warnings,  which  are  carried  on 
various parts of the machine. Refer to the 
next page for a location diagram and the 
wording of these warnings. 

 

 

Never  allow  an  inadequately  trained 
person to attach or operate the sprayer. 

 

 

Do  not  operate  the  sprayer  whilst 
wearing loose clothing, unrestrained long 
hair,  jewellery  or  anything  which  could 
become 

entangled 

in 

rotating 

components or limit your vision. 

 

 

Wear ear  protection when  operating the 
sprayer  on  a  tractor  which  is  not  fitted 
with a sound proofed cabin. 

 

 

Ensure the linkage capacity of the tractor 
is  suitable  for  the  loaded  mass  of  the 
sprayer.  Refer  to  the  tractor  operator’s 
manual  for  safe  working  loads  and 
relevant tractor safety instructions. 

 

 

Exercise extreme care when operating in 
hilly  or  uneven  terrain  to  ensure 
adequate  stability.  Refer  also  to  the 
tractor  manufacturer’s  operating  and 
safety instructions. 

 

 

Do  not  operate  the  pump  at  speeds 
greater than 540 PTO rpm and less than 
400rpm. 

 

 

Do not operate the sprayer without all of 
the  tractor  and  sprayer  safety  shields  in 
place.  Carefully  check  that  PTO  and 
driveline shields are correctly installed.  

 

 

Stop  the  tractor  PTO,  apply  the  parking 
brake  and  switch  off  the  tractor  engine 
before  approaching  the  sprayer  and 
performing any work on it. 

 

 

Disconnect  the  PTO  shaft  at  the  tractor 
and  ensure  the  sprayer  is  properly 
supported 

before 

performing 

any 

maintenance work. 

 

 

Before  use  of  any  chemicals

  refer  to 

the  chemical  manufacturer’s  label  and 
safety  instructions  for  safe  handling 
procedures  and  correct  method  of  use. 
Always  use  the  recommended  personal 
protective clothing and equipment. 

 

 

Always wear gloves when removing and 
cleaning filters. 

 

 

Dispose of empty chemical containers in 
accordance with the instructions supplied 
by the chemical manufacturer. 

 

 

Ensure that all operators and associated 
personnel  are  familiar  with  the  legal 
regulations  and  codes  of  practice  that 
apply  to  the  safe  use  and  storage  of 
spray chemicals. 

 

 

Ensure chemicals are kept away from 
the fresh water tank. 

Never drink water 

from the fresh water tank

 

 

Ensure all bystanders are at a safe 
distance from the machine. 

 

 

Do not use flammable liquids or gases 
in the sprayer. 

 

 

Summary of Contents for Super 1100L Series

Page 1: ...Operators Manual MANLINK 4D REV H 12 11 20 400L 600L 800 1100L Super Series Linkage Sprayer...

Page 2: ...nd safety and incorporate many innovative features To ensure continued efficient performance and safe operation of your sprayer you need to read this manual thoroughly and fully familiarise yourself w...

Page 3: ...om Attachment 11 Fresh water Tank Toolbox Spray Booms 11 Spray Guns Hose Reels and Foam Marker 12 Starting the sprayer 13 Chemical induction probe 1100L only 13 Shutdown 13 General Spraying Informatio...

Page 4: ...This Warranty is in addition to any other rights and remedies available to consumers under the law This Warranty Covers Only conditions resulting directly from defects in workmanship or material under...

Page 5: ...me care when operating in hilly or uneven terrain to ensure adequate stability Refer also to the tractor manufacturer s operating and safety instructions Do not operate the pump at speeds greater than...

Page 6: ...Decal Positions 6 DEC232 INS142 INSTRUCTION BOOKLET DEC52 DEC101213P DEC101213P US4 DEC232 DEC52 BOTH SIDES DEC07 INS142 US4...

Page 7: ...other salty concentrations Water with a temperature above 40 C and less than 5 C Any type of varnish Solvents and thinners for any type of varnish Any type of fuel or lubricant Liquids containing gra...

Page 8: ...er single side 16 litre foam marker double side electric 57 litre foam marker double side electric Spray Booms Field Boom 6m 8m or 10m Galvanized steel truss Three section horizontal fold Spring loade...

Page 9: ...eference Set the linkage height so that the ends of the two shafts are at their closest distance Install the PTO shaft making sure that there is at least 25mm of telescopic travel remaining between th...

Page 10: ...ON To Clean The Filter 1 Disengage the PTO 2 Turn the ball valve to the Off position 3 o clock 3 Unscrew the Filter Nut Remove the Filter Bowl 4 Clean the Filter 5 Secure the filter Filter Bowl in po...

Page 11: ...closing the lid Spray Booms A variety of booms may be used with Silvan linkage sprayers depending upon the model and field application All have stainless steel spray lines fitted with non drip nozzle...

Page 12: ...will whip Foam Marker Refer to the Foam Marker Operator s Manual for installation and operating procedures relevant to the foam marker Spray Guns and Hose Reels To operate the spray gun prime the pump...

Page 13: ...ion rate and other factors refer to the Calibration section of this manual Open the outlet valves that are connected to the boom or other spraying device to start spraying Under most boom spraying con...

Page 14: ...00 increases droplet size For an equivalent pressure and fan angle a larger size jet produces larger droplets Nozzle Height and Spacing To achieve a uniform spray pattern without gaps the output from...

Page 15: ...ction Chart on the following pages for the particular type and size fitted If the volume collected is too low the operating pressure may be increased and the test repeated alternatively if the volume...

Page 16: ...mple of how to use the calibration chart is shown below Using the Calibration Charts For example a rate of 96 l ha can be achieved at a ground speed of 10 kmh using 3 0 Bar pressure with a 110 02 yell...

Page 17: ...ype oil b If this happens after many hours of operation and continues after 1 or 2 top ups it is a symptom of diaphragm swelling caused by restricted suction dirty filter collapsed suction hose or che...

Page 18: ...ck for entry of air caused by entry of air caused by hose wear loose fittings worn joints 2 There are no small leaks or drips on the suction side of the pump when it is stationary If this occurs it me...

Page 19: ...e regulator valve and seats worn Pressure gauge faulty Pump diaphragms ruptured pump oil grey or milky Worn nozzles or capacity of nozzles greater than capacity of the pump Worn pump inlet outlet valv...

Page 20: ...1 144 AUSTRALIA HEAD OFFICE 68 Atlantic Drive Keysborough Victoria 3173 Telephone 1300 745 826 Fax 1800 745 826 www silvan com au NEW ZEALAND 22 Sunshine Ave Te Rapa Hamilton 3241 Telephone 0508 745 8...