background image

 

Specifications

 

 

 

BP75/20 

Pumps 

Positive displacement oil-backed diaphragm  
pump of varying size depending on sprayer  
specification.  Output  at  540  PTO  rpm  and 
maximum operating pressure as shown below. 
  
Pump            Output    Pressure      No.of 
Model 

    l/min       Bar  psi    Diaphragms 

BP   60/20        58         20  290           2 
BP   75/20        67

 

        20  290           3 

BP   125/20      117       20  290           3 

Note

 Maximum operating speed 540 rpm.                                      

         Minimum operating speed 400 rpm. 
These  pumps  have  been  designed  and 
constructed  solely  to  pump  agricultural  liquid 
chemicals,  normally  used  for  pest,  weed  and 
fungus control. 

They must not to be used to pump: 

  Liquids  with  a  density  and  viscosity  greater 

than water. 

  Chemical  products  if  the  compatibility  with 

the materials of the pump is not known. 

  Sea water or other salty concentrations. 

  Water  with  a  temperature  above  40°C  and 

less than 5°C. 

  Any type of varnish. 

  Solvents and thinners for any type of varnish. 

  Any type of fuel or lubricant. 

  Liquids  containing  granules  or  floating  solid 

parts. 

  Chlorine. 

  For  special  liquids  please  contact  Silvan 

service department

 

Pump Identification

 

The following data is found on the pump  name 
plate: 
1. Pump Type 
2. Maximum Delivery (at 0 Bar) 
3. Delivery at Maximum Pressure 
4. Maximum Pressure Permitted in Pump 
5. Maximum RPM 
6. Manufacturer's Serial No

 

 

2          3           4            1            5            6 
 

 

 

 
 

Component Identification 

Refer to the following diagrams for the position 
of  the  various  components  relating  to  your 
pump. 
 

1. Mounting Base              3. Pump Shaft                     
4. Oil Reservoir                 5. Pressure Accumulator    
6. Pump Head                   7. Inlet Hose Barb               
8. Inlet Valve Cap              9. Pump Crankcase            
11. Inlet Manifold             12. Delivery Manifold 
13. Oil Level Cap             15. PTO Safety Shield      
16. Delivery  Coupling      17. Oil Cap 

  

                       
 

 

 
 

 

 
 
 

 

BP60/20 

BP125/20 

 

 

Summary of Contents for Super 1100L Series

Page 1: ...Operators Manual MANLINK 4D REV H 12 11 20 400L 600L 800 1100L Super Series Linkage Sprayer...

Page 2: ...nd safety and incorporate many innovative features To ensure continued efficient performance and safe operation of your sprayer you need to read this manual thoroughly and fully familiarise yourself w...

Page 3: ...om Attachment 11 Fresh water Tank Toolbox Spray Booms 11 Spray Guns Hose Reels and Foam Marker 12 Starting the sprayer 13 Chemical induction probe 1100L only 13 Shutdown 13 General Spraying Informatio...

Page 4: ...This Warranty is in addition to any other rights and remedies available to consumers under the law This Warranty Covers Only conditions resulting directly from defects in workmanship or material under...

Page 5: ...me care when operating in hilly or uneven terrain to ensure adequate stability Refer also to the tractor manufacturer s operating and safety instructions Do not operate the pump at speeds greater than...

Page 6: ...Decal Positions 6 DEC232 INS142 INSTRUCTION BOOKLET DEC52 DEC101213P DEC101213P US4 DEC232 DEC52 BOTH SIDES DEC07 INS142 US4...

Page 7: ...other salty concentrations Water with a temperature above 40 C and less than 5 C Any type of varnish Solvents and thinners for any type of varnish Any type of fuel or lubricant Liquids containing gra...

Page 8: ...er single side 16 litre foam marker double side electric 57 litre foam marker double side electric Spray Booms Field Boom 6m 8m or 10m Galvanized steel truss Three section horizontal fold Spring loade...

Page 9: ...eference Set the linkage height so that the ends of the two shafts are at their closest distance Install the PTO shaft making sure that there is at least 25mm of telescopic travel remaining between th...

Page 10: ...ON To Clean The Filter 1 Disengage the PTO 2 Turn the ball valve to the Off position 3 o clock 3 Unscrew the Filter Nut Remove the Filter Bowl 4 Clean the Filter 5 Secure the filter Filter Bowl in po...

Page 11: ...closing the lid Spray Booms A variety of booms may be used with Silvan linkage sprayers depending upon the model and field application All have stainless steel spray lines fitted with non drip nozzle...

Page 12: ...will whip Foam Marker Refer to the Foam Marker Operator s Manual for installation and operating procedures relevant to the foam marker Spray Guns and Hose Reels To operate the spray gun prime the pump...

Page 13: ...ion rate and other factors refer to the Calibration section of this manual Open the outlet valves that are connected to the boom or other spraying device to start spraying Under most boom spraying con...

Page 14: ...00 increases droplet size For an equivalent pressure and fan angle a larger size jet produces larger droplets Nozzle Height and Spacing To achieve a uniform spray pattern without gaps the output from...

Page 15: ...ction Chart on the following pages for the particular type and size fitted If the volume collected is too low the operating pressure may be increased and the test repeated alternatively if the volume...

Page 16: ...mple of how to use the calibration chart is shown below Using the Calibration Charts For example a rate of 96 l ha can be achieved at a ground speed of 10 kmh using 3 0 Bar pressure with a 110 02 yell...

Page 17: ...ype oil b If this happens after many hours of operation and continues after 1 or 2 top ups it is a symptom of diaphragm swelling caused by restricted suction dirty filter collapsed suction hose or che...

Page 18: ...ck for entry of air caused by entry of air caused by hose wear loose fittings worn joints 2 There are no small leaks or drips on the suction side of the pump when it is stationary If this occurs it me...

Page 19: ...e regulator valve and seats worn Pressure gauge faulty Pump diaphragms ruptured pump oil grey or milky Worn nozzles or capacity of nozzles greater than capacity of the pump Worn pump inlet outlet valv...

Page 20: ...1 144 AUSTRALIA HEAD OFFICE 68 Atlantic Drive Keysborough Victoria 3173 Telephone 1300 745 826 Fax 1800 745 826 www silvan com au NEW ZEALAND 22 Sunshine Ave Te Rapa Hamilton 3241 Telephone 0508 745 8...

Reviews: