Silicon CPV plc
Akhter House, Perry Road, Harlow, Essex, CM18 7PN, UK
Tel +44 (0) 1279 821200 Email [email protected]
Page 24 of 32
4.
Unplug the connector by unscrewing, then pulling the connector
apart.
5.
The old battery and controller pack can now be completely removed
from the light head
6.
Using a new battery and controller pack reverse the removal
process to install the new pack.
7.
Place the unit in ON mode and please ensure the rubber plug is re-
inserted after inspection to prevent water ingress.