Operating manual - English
Optika
44
Copyright Silca 2017
-
When the illuminators stop flashing the display will show:
Press ESC to go back to the previous menus.
6.4.7.3
CHECK CUTS AREA
Note: this operation is necessary when the image is out of focus or faulty and must be carried out
only on the advice of SILCA after-sales staff.
The operation is used to gauge the clamp illumination area (position of key).
The display will show:
-
Turn the clamp (A) (fig. 7, page 7) right and left during flashing, making sure that every flash of the
red led corresponds to one position. The positions must vary from the far right to the far left, including
the intermediate positions.
ATTENTION: do not open the clamp during rotation.
Note: It is important that the clamp is on one position every time the led flashes, and is re-positioned
before the next flash.
The procedure can be repeated a number of times if you are not sure it has been carried out properly.
Press ESC to go back to the previous menus.
6.4.7.4
TELECAMERA and LED
Note: this function will be available in the next software release.
6.4.7.5
DISPLAY
Note: this function will be available in the next software release.
6.4.7.6
KEYBOARD
Note: this function will be available in the next software release.
Check profile area
Open and close
the clamp
Check completed
Check cuts area
Turn the clamp
right and left
Check cuts area
Turn the clamp
right and left
Check completed