Operating manual - English
MARKER 2000
Copyright Silca 2002
11
4.2
Securing the keys
Take the clamp to the “tracking” position to facilitate positioning of the key. Ensure that the glass slide
diffusor (P) is not in the way by rotating it outwards with knob (P1) (fig. 13).
1) loosen the jaw-locking knob (G1);
2) select the side of the key to be marked, push the clamp (G) (fig. 13) and place the key with its back
on the right-hand (F2) or left-hand (F3) stop, according to the shape of the profile; keys with cuts on
both sides must be positioned in the centre and secured with the clamp inside the groove (fig. 14).
3) move the clamp (G) into the ideal position for securing the key (inside the groove) and tighten the
knob (G1); the clamp (G) can be moved a maximum of 10 mm along the X axis.
4) loosen the locking knob (F), move the clamp slide (E) so that the key head is butting against the
head stop (F1) and lock the slide with the knob (F).
5) to position other keys with the same features, simply adjust the clamp (G).
Fig. 13
Fig. 14
Fig. 15
P
P1
F
G
10 mm
G1
F3
F2
E
F
F
G1
P
F1
P1
G
E