Operating manual - English
MARKER 2000
Copyright Silca 2002
35
9
MAINTENANCE
WARNING: for repairs or replacement of parts for maintenance, the ‘CE’ mark is guaranteed only if original spare
parts provided by the manufacturer are used.
Although the electronic marking machine MARKER 2000 does not require special maintenance, it is
advisable to check and, if necessary, replace the parts subject to wear (belt, marking punch, etc.) and
electrical/electronic parts (fuses, circuit boards, etc.) in the event of faulty operation.
Replacement is simple and can be carried out by the operator.
WARNING: for normal servicing of the burnished mechanical parts, we recommend using lubricants or protective oil,
e.g. WD40 or similar. Do not apply to the parts used for electrical contact (clamps, gauging templates, etc.). Do not
contaminate the electronic parts with the oil.
Before starting any type of maintenance (checks or replacements) read the instructions below:
•
never carry out maintenance or servicing with the machine switched on
•
always remove the mains plug
•
follow all the instructions in the manual to the letter
•
use original spare parts
9.1
Trouble shooting
FAULT
PROBABLE CAUSE
Machine on, no message
on display.
Check if the rear fan is
working:
YES a) check display connection
b) replace display
(ch.9.6, page 40)
NO a) check general fuses in power socket (ch.9.7, page 40)
b) check fuses on electronic control circuit board (ch.9.7, page 40)
c) replace electronic control circuit board (ch.9.8, page 42)
Working head not return-
ing to the idle position
a) check fuse (F1) on control circuit board (when cut off, display shows the message: “CHECK
FUSE F1” (ch.9.7, page 40)
b) carry out a TEST 101 (ch.8, page 33) on the operation of the X and Y axis sensors
Working head not moving
a) check fuse F3 on electronic control circuit board (ch.9.7, page 40)
b) check wiring between electronic control circuit board and motors
c) replace electronic control circuit board (ch.
9.8, page 42)
Keyboard not working
a) check wiring between electronic control circuit board and keyboard
b) replace electronic control circuit board (ch.
9.8, page 42)
c) replace keyboard
Tracking laser not illumi-
nating
a) check fuse F1 on electronic control circuit board (when cut off, display shows the message:
“CHECK FUSE F1”
(ch.9.7, page 40)
b) check that the disk is inserted properly into the tracking block and that the clamp is not in the
marking position
c) check operation of safety microswitch on tracking unit (remove the unit and use an ohmmeter
(ch.
9.2, page 36)
d) check wiring between electronic control circuit board and tracking unit
e) carry out a TEST 102 (ch.
8, page 33)
on operation of clamp detector microswitch
f) replace tracking unit (ch.
9.2, page 36)
g) replace electronic control circuit board (ch.
9.8, page 42)
Marking punch
not working
a) check fuse F3 on the electronic control circuit board (ch.
9.7, page 40)
b) check the wiring between electronic control circuit board and the magnet
c) replace the magnet
d) replace the electronic control circuit board (ch.
9.8, page 42)
Message on display:
check the operation of the cooling fan.
If the fan is working properly, leave the machine off and contact a Silca Service Centre
ALARM
Temperature is over
max. foreseen
Turn off Marker!