The above sequence will set up six (6) calls. In the first call, endpoints are not specified so
endpoints 1 and 2 are allocated. In calls 2 and 3, channels are not specified, so channels 2-5 are
allocated. In the fourth (4
th
) call, endpoints 5 and 6 are assigned, as they are the “next available”
endpoints. In the fifth line above, a new call leg is created with channel 8 and endpoint 8
specified, and Call Id 5 assigned (given explicitly). In the sixth call, each leg is set up separately.
Notes about the above call setups:
Call Ids 1 thru 4 are assigned for first 4 calls, a Call Id value of 5 is given explicitly for
the fifth call, but only one leg of the call is active, so this call ID is reserved. A Call Id
value of 10 is given explicitly for the sixth call
only one call can be set up each time ‘s’ is pressed
Call Id values are “one based”. The maximum Call Id value is 255
If a digital scope is connected to the CTBus between the DS3 module and SigC641x modules,
then the scope should show a display similar to Figure 4-18 below.
Figure 4-18, CTBus between SigC641x and DS3 modules, with voice data active