background image

32

33

EU-DECLARATION OF CONFORMITY 

We, SIGMA-ELEKTRO GmbH, Dr. Julius Leber Str. 15, D- 67433 Neustadt / 
Weinstraße, declare under our responsibility that the product ROX GPS 11.0 
and the transmitter R1 Duo and R2 Duo are compliant with the essential 
requirements and other relevant requirements of the RED Directive 2014 / 53 / EU 
and the RoHS Directive 2011/65/EU. 

The CE declaration can be found at: ce.sigmasport.com/rox11

Federal Communication Commission Interference Statement

This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: 
(1) This device may not cause harmful interference, and 
(2) this device must accept any interference received,  
including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one of
the following measures:

 

− Reorient or relocate the receiving antenna.

 

− Increase the separation between the equipment and receiver.

 

− Connect the equipment into an outlet on a circuit different from that  

to which the receiver is connected.

 

− Consult the dealer or an experienced radio/TV technician for help.

FCC Caution: 
Any changes or modifications not expressly approved by the party responsible 
for compliance could void the user’s authority to operate this equipment. This 
transmitter must not be co-located or operating in conjunction with any other 
antenna or transmitter.

Radiation Exposure Statement:
The product comply with the FCC portable RF exposure limit set forth for an
uncontrolled environment and are safe for intended operation as described in
this manual. The further RF exposure reduction can be achieved if the product
can be kept as far as possible from the user body or set the device to lower
output power if such function is available.

Industry Canada statement

This device complies with ISED’s licence-exempt RSSs. Operation is subject
to the following two conditions: 
(1) This device may not cause harmful interference, and 
(2) this device must accept any interference received,
including interference that may cause undesired operation.

Le présent appareil est conforme aux CNR d’ ISED applicables aux appareils
radio exempts de licence. L’exploitation est autorisée aux deux conditions
suivantes :
(1) le dispositif ne doit pas produire de brouillage préjudiciable, et 
(2) ce dispositif doit accepter tout brouillage reçu, y compris un brouillage
susceptible de provoquer un fonctionnement indésirable.

Do not disassemble, modify or repair this product, as this may cause a fire,
electric shock or product damage. Any modification will void the warranty of
this product.

Ne pas démonter, modifier ni réparer ce produit, car cela pourrait provoquer
un feu, un choc électrique ou un dommage produit. Toute modification
annulera la garantie de ce produit.

This Class B digital apparatus complies with Canadian
CAN ICES-3 (B)/NMB-3 (B).
Cet appareil digital de classe B est homologué CAN ICES-3 (B)/NMB-3 (B)
pour le Canada.

Radiation Exposure Statement:
The product comply with the Canada portable RF exposure limit set forth for
an uncontrolled environment and are safe for intended operation as described
in this manual. The further RF exposure reduction can be achieved if the
product can be kept as far as possible from the user body or set the device to
lower output power if such function is available.

Déclaration d’exposition aux radiations:
Le produit est conforme aux limites d’exposition pour les appareils portables
RF pour les Etats-Unis et le Canada établies pour un environnement non
contrôlé. Le produit est sûr pour un fonctionnement tel que décrit dans ce
manuel. La réduction aux expositions RF peut être augmentée si l’appareil
peut être conservé aussi loin que possible du corps de l’utilisateur ou que le
dispositif est réglé sur la puissance de sortie la plus faible si une telle fonction
est disponible.

EN

Summary of Contents for ROX GPS 11.0

Page 1: ...1 TRACK NAVI BAROMETRIC COMPATIBLE COMPATIBLE COMPATIBLE eTap EN ROX GPS 11 0 USER GUIDE MORE INFORMATION WWW SIGMA QR COM...

Page 2: ...ORT Your new ROX GPS 11 0 will be a loyal companion for your bike trips for years to come To familiarise yourself with and learn how to use the many functions of your new bike computer please read the...

Page 3: ...4 5 2 Mounting Only included in the complete set Only included in the complete set Only included in the complete set or max 10 mm 0 4 inch max 10 mm 0 4 inch EN or CLICK...

Page 4: ...paired are activated Start the search using SEARCH ALL or SEARCH SENSOR desired sensor type After a few seconds the sensor and the associated sensor ID are displayed Select the desired sensor to conn...

Page 5: ...reduce a value to be set ONLY IN TRAINING with active workout Press and hold to move to the next phase of your defined workout PLUS button Use this button to change the training views during training...

Page 6: ...PROFILE has been selected it searches for the GPS After a successful search of the GPS the various views can be changed using the PLUS or MINUS button To start the training or the recording the START...

Page 7: ...daily newspaper or at airports 4 GPS calibration If you do not have a reference point or any indication of your current altitude you can determine this by means of GPS The accuracy of the displayed al...

Page 8: ...follow the description in the LINK app 6 Load track This function enables you to select start display and delete finished or stored tracks NOTE The track management can also be performed quickly and...

Page 9: ...pressing the START button the track starts 6 2 2 Start track reverse Use Start track reverse to reverse the direction of the selected track 6 2 3 Show track Select Show track to display the route for...

Page 10: ...you want to perform an interval training you can define the first phase as a warm up phase the second as an interval e g 5 x 1000 m with 1 00 min recovery with the final cool down phase Up to 10 phase...

Page 11: ...he personal bests Use the PLUS and MINUS buttons to select the item Reset personal best and press the START button 10 Settings All important functions can be set either directly on the ROX GPS 11 0 or...

Page 12: ...an set three different home altitudes on the ROX GPS 11 0 Home altitude 1 Home altitude 2 Home altitude 3 Altitude points list The altitude measurement points from the IAC altitude calibration are sto...

Page 13: ...better 10 5 8 Intensity zones HR The ROX GPS 11 0 has four intensity zones which make it easier to monitor your training The values are automatically calculated on the basis of your maximum heart rat...

Page 14: ...speed downhill Average rate of descent Maximum rate of descent Average slope downhill Maximum slope downhill GPS Accuracy Battery capacity in Time to destination Estimated time of arrival Dist to des...

Page 15: ...omatic lap Pedalling time in automatic lap Pedalling index in automatic lap Auto lap list Pedalling time Pedalling index Balance 3 sec Average balance 10 sec Average balance 30 sec Average balance Ave...

Page 16: ...ntracting partners for defects in line with legal provisions The warranty does not extend to batteries In the event of a warranty claim please contact the retailer from whom you purchased your bike co...

Page 17: ...set forth for an uncontrolled environment and are safe for intended operation as described in this manual The further RF exposure reduction can be achieved if the product can be kept as far as possibl...

Page 18: ...e 15 D 67433 Neustadt Weinstra e Tel 49 0 63 21 9120 0 Fax 49 0 63 21 9120 34 E mail info sigmasport com SIGMA SPORT USA North America 1860B Dean St St Charles IL 60174 U S A Tel 1 630 761 1106 Fax 1...

Reviews: