A5E32106153
SITRANS Probe LR – QUICK START MANUAL
Page EN-7
m
mmmm
Englis
h
• For wiring requirements: follow local regulations.
• Approved dust-tight and water-tight conduit seals are required for outdoor Type 4X /
NEMA 4X, Type 6 / NEMA 6, IP67, IP68 locations.
• Refer to
Instructions specific to hazardous area installations (Reference European ATEX
Directive 94/9/EC, Annex II, 1/0/6)
on page 8.
• For power demands, see
Loop power
on page 4 of Appendix A.
2. Non-incendive wiring (FM US only)
• For power demands, see
Loop power
on page 4 of Appendix A.
FM Intrinsically Safe connection drawing
number A5E01003040 can be downloaded from the product page of our website at:
www.siemens.com/probelr. Go to Support > Installation Drawings > Level Measurement >
Continuous - Radar.
Device nameplate (FM)
WARNING: Possible Static Hazard, Do Not Rub Or Clean On Site.
Class I, Div 1, Group A, B, C, D
Class II, Div 1, Group E, F, G
Class III
Temp. Code: T4
FM per drawing A5E01003040
FCC ID: NJA-LR200
Vmax = 30 V
Imax = 120 mA
Pmax = 0.8 W
Ci = 15 nF
Li = 0.1 mH
Assembled in Canada with domestic and imported parts
Siemens Milltronics Process Instruments, Peterborough
SITRANS Probe LR
7MLxxxx-xxxxx-xxxx
Serial No: GYZ / S1034567
Encl.: NEMA / TYPE 4X, 6, IP67, IP68
Amb.Temp.: – 40 °C to 80 °C
Power Rating: 24V
Max., 4 - 20mA
Nom., 30 V
HART
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions 1)This device may not cause harmful interference and
2)This device must accept any interference received, including interference that
may cause undesired operation
6.3 GHz
CSA Intrinsically Safe connection drawing
number A5E01003039 can be downloaded from the product page of our website at:
www.siemens.com/probelr. Go to Support > Installation Drawings > Level Measurement >
Continuous - Radar.
Device nameplate (CSA)
WARNING: Possible Static Hazard, Do Not Rub Or Clean On Site.
Class I, Div 1, Group A, B, C, D
Class II, Div 1, Group E, F, G
Class III
Temp. Code: T4
CSA per drawing A5E01003039
IC: 267P - LR200
Vmax = 30 V
Imax = 120 mA
Pmax = 0.8 W
Ci = 15 nF
Li = 0.1 mH
Assembled in Canada with domestic and imported parts
Siemens Milltronics Process Instruments, Peterborough
SITRANS Probe LR
7MLxxxx-xxxxx-xxxx
Serial No: GYZ / A1034567
Encl.: NEMA / TYPE 4X, 6, IP67, IP68
Amb.Temp.: – 40 °C to 80 °C
Power Rating: 24V
Max., 4 - 20mA
Nom., 30 V
HART
6.3 GHz
159134
Assembled in Canada with domestic and imported parts
Siemens Milltronics Process Instruments, Peterborough
SITRANS Probe LR
7MLxxxx-xxxxx-xxxx
Serial No: GYZ / S1034567
Encl.: NEMA / TYPE 4X, 6, IP67, IP68
Amb.Temp.: – 40 °C to 80 °C
Power Rating: 24V
Max., 4 - 20mA
Nom., 30 V
HART
6.3GHz
Class I,Div.2,
Group A,B,C,D
Temp.Code:T5
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions
1)This device may not cause harmful interference and
2)This device must accept any interference received, including
interference that may cause undesired operation
FCC : NJA–LR200
FM Class 1, Div 2 connection drawing
number 23650537 can be downloaded from the product page of our website at:
www.siemens.com/probelr. Go to Support > Installation Drawings > Level Measurement >
Continuous - Radar.
Siemens Industrial Spares