A5E33329501
SITRANS LUT400 (HART) – OPERATING INSTRUCTIONS
Page 241
m
mmmm
Tr
oub
leshoot
in
g
Symptom
Cause
Action
No response when
echo profile requested
via LUI (
Transducer is disabled.
Set Transducer Enable (3.3.1.) on
page 205 to ENABLED, then
request an echo profile.
Configuration error 130
displayed
Relay/pump configuration
errors - possible causes
include:
• A relay is assigned to more
than one function (e.g. relay 2
is assigned to both an
external totalizer and a
pump).
• Pump setpoints are out of
order.
• Wall Cling adjustment range
is too large.
• Verify that each relay is
assigned to one function only.
Review relay assignments
under Pump Control (page 151)
and Other Control functions
(page 175).
• Verify that all ’ON’ setpoints are
greater than their respective
’OFF’ setpoints for pump down
applications (or vica versa for
pump up applications).
• Ensure range set in Level
Setpoint Variation (2.7.2.1.2.) on
page 154 has not caused ’ON’ or
’OFF’ setpoints to overlap.
Echo profile request
results in an error icon
that displays for 5 sec-
onds before returning
to the echo profile
request menu.
Another external communica-
tion is trying to access an echo
profile at the same time.
Wait for several seconds and then
retry the echo profile request, or
disconnect / disable any external
communications that may be
requesting an echo profile.
Data log files are empty
or logging has stopped.
• Data Logging is not enabled.
• USB extension cable has
been used (although may not
currently be connected).
• Verify that Data Logging is
enabled. See Data Logging
(2.10.) on page 173.
• If a USB extension cable has
been used (remove if currently
connected), a power reset of
the device is required to restart
Data Logging.
Summary of Contents for SITRANS LUT400
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ...Controllori ad ultrasuoni Manuale d istruzioni 08 2012 SITRANS LUT400 HART SITRANS ...
Page 51: ...Pagina 32 SITRANS LUT400 HART MANUALE D ISTRUZIONI 7ML19985MV51 mmmmm Collegamento Note ...
Page 81: ...Pagina 62 SITRANS LUT400 HART MANUALE D ISTRUZIONI 7ML1998MV51 mmmmm Messa in esercizio Note ...
Page 151: ...Pagina 132 SITRANS LUT400 HART MANUALE D ISTRUZIONI 7ML19985MV51 mmmmm Funzionamento AMS Note ...
Page 247: ...Pagina 228 SITRANS LUT400 HART MANUALE D ISTRUZIONI 7ML19985MV51 mmmmm Manutenzione Note ...
Page 271: ...Pagina 252 SITRANS LUT400 HART MANUALE D ISTRUZIONI 7ML19985MV51 mmmmm Dati tecnici Note ...
Page 287: ...Pagina 268 SITRANS LUT400 HART MANUALE D ISTRUZIONI 7ML19985MV51 mmmmm App A Rif tecnico Note ...
Page 303: ...Note Notes fm Page 2 Thursday October 11 2001 8 48 AM ...
Page 304: ...IQ300IX fm Page 5 Tuesday October 2 2001 1 43 PM ...
Page 306: ...Operating Instructions SITRANS LUT400 HART 12 2014 Edition Ultrasonic Controllers ...
Page 319: ...Page 6 SITRANS LUT400 HART OPERATING INSTRUCTIONS A5E33329501 mmmmm Safety Notes Notes ...
Page 345: ...Page 32 SITRANS LUT400 HART OPERATING INSTRUCTIONS A5E33329501 mmmmm Connecting Notes ...
Page 375: ...Page 62 SITRANS LUT400 HART OPERATING INSTRUCTIONS 7ML1998MV01 mmmmm Commissioning Notes ...
Page 443: ...Page 130 SITRANS LUT400 HART OPERATING INSTRUCTIONS A5E33329501 mmmmm Operation Browser Notes ...
Page 445: ...Page 132 SITRANS LUT400 HART OPERATING INSTRUCTIONS A5E33329501 mmmmm Operation AMS Notes ...
Page 447: ...Page 134 SITRANS LUT400 HART OPERATING INSTRUCTIONS A5E33329501 mmmmm Operation FC375 Notes ...
Page 449: ...Page 136 SITRANS LUT400 HART OPERATING INSTRUCTIONS A5E33329501 mmmmm Operation FDT DTM Notes ...
Page 543: ...Page 230 SITRANS LUT400 HART OPERATING INSTRUCTIONS A5E33329501 mmmmm Maintenance Notes ...
Page 561: ...Page 248 SITRANS LUT400 HART OPERATING INSTRUCTIONS A5E33329501 mmmmm Troubleshooting Notes ...
Page 567: ...Page 254 SITRANS LUT400 HART OPERATING INSTRUCTIONS A5E33329501 mmmmm Technical Data Notes ...
Page 584: ...Page 271 SITRANS LUT400 HART OPERATING INSTRUCTIONS A5E33329501 mmmmm App A Technical Ref ...
Page 585: ...Page 272 SITRANS LUT400 HART OPERATING INSTRUCTIONS A5E33329501 mmmmm App A Technical Ref ...