
Installing/mounting
4.5 Disassembly
SITRANS LR250 with FOUNDATION FIELDBUS
Operating Instructions, 09/2021, A5E32221411-AH
35
①
Orientation mark for leak detection port
②
Leak detection port
4.5
Disassembly
DANGER
Pressure applications
Danger to personnel, system and environment will result from improper disassembly.
•
Never attempt to loosen, remove, or disassemble process connection while vessel
contents are under pressure.
WARNING
Incorrect disassembly
The following risks may result from incorrect disassembly:
- Injury through electric shock
- Risk through emerging media when connected to the process
- Risk of explosion in hazardous area
In order to disassemble correctly, observe the following:
•
Before starting work, make sure that you have switched off all physical variables such as
pressure, temperature, electricity etc. or that they have a harmless value.
•
If the device contains hazardous media, it must be emptied prior to disassembly. Make
sure that no environmentally hazardous media are released.
•
Secure the remaining connections so that no damage can result if the process is started
unintentionally.