Technical specifications
11.5 Environmental
SITRANS LR250 with FOUNDATION FIELDBUS
182
Operating Instructions, 09/2021, A5E32221411-AH
11.5
Environmental
Note
•
For the specific configuration you are about to use or install, check transmitter nameplate
and see Approvals (Page 183).
•
Use appropriate conduit seals to maintain IP or NEMA rating.
Location
indoor/ outdoor
Altitude
5000 m (16,404 ft) max.
Ambient temperature
−40 to +80 °C (−40 to +176 °F)
Relative humidity
suitable for outdoor
Type 4X, Type 6, IP67, IP68 enclosure (see note above)
Installation category
I
Pollution degree
4
11.6
Process
Note
The maximum temperature is dependent on the process connection, antenna materials, and
vessel pressure. For more detailed information see Maximum Process Temperature Chart
(Page 241) and Process Pressure/Temperature derating curves (Page 242).
Temperature at process con-
nection
Stainless steel horn an-
tenna (Threaded or
Flanged):
with FKM O-ring
-40 to +200 °C (-40 to +392 °F)
with FFKM O-ring
-20 to +200 °C (-4 to +392 °F)
Painted aluminum horn, with polypropylene
lens antenna version, threaded PVDF antenna
-40 to +80 °C (-40 to +176 °F)
PTFE flanged encapsulated antenna (FEA)
-40 to +170 °C (-40 to +338 °F)
Hygienic encapsulated antenna (HEA)
-40 to +170 °C (-40 to +338 °F)
with FKM seals used on process connec-
tion: -20 to +170 °C (-4 to +338 °F)
with EPDM seals used on process connec-
tion: -40 to +120 °C (-40 to +248 °F)
Pressure (vessel)
Refer to process connection tag and Pro-