Settings
B.6 Dimension dependent settings, SONOKIT 1-path
SITRANS FUS080 transmitter
Operating Instructions, 07/2012, A5E03059912-02
89
B.6
Dimension dependent settings, SONOKIT 1-path
(Used dimension unit is [m])
Nominal size *)
Max. vol. flow
Pipe diameter
Path angle
Path length
[mm]
[inch]
[m3/h]
[m]
[º]
[m]
DN 100
4
100
0.1071
45
0.1795
DN 125
5
150
0.1317
45
0.2143
DN 150
6
220
0.1593
45
0.2533
DN 200
8
380
0.2083
60
0.2584
DN 250
10
600
0.2604
60
0.3185
DN 300
12
850
0.3098
60
0.3756
DN 350
14
1000
0.3396
60
0.4100
DN 400
16
1300
0.3904
60
0.4687
DN 450
18
1700
0.4500
60
0.5375
DN 500
20
2200
0.4920
60
0.5860
DN 550
22
2600
0.5500
60
0.6529
DN 600
24
3200
0.6016
60
0.7125
DN 650
26
3600
0.6500
60
0.7684
DN 700
28
4200
0.6952
60
0.8206
DN 750
30
4800
0.7500
60
0.8839
DN 800
32
5500
0.7968
60
0.9379
DN 900
36
7500
0.9100
60
1.0686
DN 1000
40
9000
1.0000
60
1.1726
DN 1100
44
10000
1.1000
60
1.2880
DN 1200
48
13200
1.2000
60
1.4035
DN 1300
52
14000
1.3000
60
1.5190
DN 1400
56
16800
1.4000
60
1.6344
DN 1500
60
19000
1.5000
60
1.7499
DN 1600
64
22800
1.6000
60
1.8654
DN 1700
68
25000
1.7000
60
1.9808
DN 1800
72
27600
1.8000
60
2.0963
DN 1900
76
31000
1.9000
60
2.2118
DN 2000
80
36000
2.0000
60
2.3273
DN 2100
84
37000
2.1000
60
2.4427
DN 2200
88
42000
2.2000
60
2.5582
DN 2300
92
45000
2.3000
60
2.6737
DN 2400
96
51000
2.4000
60
2.7891
*) For FUS080 transmitter based systems only up to DN1200