IO-Link 3SU14
12.2 Electronic modules for ID key-operated switches
SIRIUS ACT 3SU1 pushbuttons and signaling devices
System Manual, 08/2018, A5E03457306020A/RS-AK/010
323
12.2.5.2
"Incremental switching mode" parameter
"Incremental switching mode" parameter
The "Incremental switching mode" parameter influences the evaluation of the current key
position.
1) "Incremental switching mode" disabled: The adjustment method is used.
●
Key position ≥ 1: The output corresponding to the current key position
-1 is switched on;
the remaining outputs 0 ... 3 are inactive.
●
Key position 0: All outputs 0 ... 3 are inactive.
Example: Key position = 2: Output 0: Off, output 1: On, output 2: Off, output 3: Off
2) "Incremental switching mode" enabled: The addition method is used.
●
Key position ≥ 1: The outputs with t
he indices from 0 to the current switch position-1 are
switched on; the remaining outputs 0 ... 3 are inactive.
●
Key position 0: All outputs 0 ... 3 are inactive.
Example: Key position = 2: Output 0: On, output 1: On, output 2: Off, output 3: Off
Settings
Description
Default setting
0
Incremental switching mode: disabled
Disabled
1
Incremental switching mode: enabled
—
12.2.5.3
"Deactivation of the switch-off function" parameter
"Deactivation of the switch-off function" parameter
The "Deactivation of the switch-off function" parameter is used to define whether or not the
selected authorization level can be deactivated by turning to the left.
The table below shows the parameter values.
Value
Description
Default setting
Disabled
The authorization levels are switched off by turning to the left.
Disabled
Enabled
The authorization levels are switched off by turning to the left.
The next lower authorization level can be selected directly
—