3SU14 modules
8.1 Overview
SIRIUS ACT 3SU1 pushbuttons and signaling devices
196
System Manual, 08/2018, A5E03457306020A/RS-AK/010
8.1.18
Electronic module for IO-Link
The electronic modules for IO-Link can be installed in 3SU1 enclosures or mounted on a
front plate.
The modules are controlled by IO-Link communication. The rated supply voltage of the
module is 24 V.
Variants
●
Front variant 6DI/2DO
For front plate mounting. The 8 digital inputs and outputs can be parameterized
individually as required. The default setting is 6 digital inputs and 2 digital outputs. The
inputs and outputs can only be parameterized by IO-Link communication.
●
Basic variant 6DI/2DO
For use in a 3SU1 enclosure. The 8 digital inputs and outputs can be parameterized
individually as required. The default setting is 6 digital inputs and 2 digital outputs. The
inputs and outputs can only be parameterized by IO-Link communication.
●
Basic variant 6DI/2DO
6DI/2DO means that the variant has 6 digital inputs and 2 digital outputs. It is not possible
to change the number of inputs and outputs.
●
Basic variant 4DI/4DO
4DI/4DO means that the variant has 4 digital inputs and 4 digital outputs. It is not possible
to change the number of inputs and outputs.
●
Basic variant 2DI/6DO
2DI/6DO means that the variant has 2 digital inputs and 6 digital outputs. It is not possible
to change the number of inputs and outputs.