Mounting
The sensor switch can be mounted on front plates and in the following enclosures of the
SIRIUS ACT series:
●
3SU1801-1AA00-1AA1 (plastic enclosure; command point in center)
●
3SU1851-1AA00-1AA1 (metal enclosure; command point in center)
●
3SU1803-3AA00-0AA1 (two-hand operation console, plastic)
●
3SU1853-3AA00-0AA1 (two-hand operation console, metal)
Note
The following applies for the American market:
The devices must only be connected with cables and connectors listed in CYJV.
Procedure (example of mounting on front plate)
1.
Insert the sensor switch into an enclosure (e.g. 3SU18..-3 two-hand operation console) or
front plate.
Align the sensor switch so that it is positioned correctly (LED).
2.
Place the holder from behind onto the sensor switch and lock it in position