10.4.5
SIEMENS telegram 902
Telegram 902 transfers as user data S_STW2, the variable SLS limit (S_SLS_LIMIT_A), the
S_ZSW2, the active SLS value of level 1 (S_SLS_LIMIT_A_ACTIVE), a counter value
(S_CYCLE_COUNT) and the safe position value in 32-bit format (S_XIST32).
Table 10-7
SIEMENS telegram 902 (telegram structure)
Output data
Input data
PZD1
PZD2
PZD3
S_SLS_LIMIT_A_ACTIVE (Page 370)
PZD4
–
PZD5
–
PZD6
10.4.6
SIEMENS telegram 903
Structure of telegram 903
Telegram 903 transmits the following user data: S_STW2, S_SLS_LIMIT_A, S_ZSW2,
S_ZSW_CAM1 and S_SLS_LIMIT_A_ACTIVE.
Output data
Input data
PZD1
PZD2
PZD3
PZD4
–
PZD5
–
S_SLS_LIMIT_A_ACTIVE (Page 370)
Data descriptions
10.4 Telegram structure and data
Safety Integrated (with SINAMICS S120)
Commissioning Manual, 02/2020, A5E46305916B AB
357