Status information
Status
Meaning
Velocity level selected
Level 1: r9720.9=0 and r9720.10=0
Level 2: r9720.9=1 and r9720.10=0
Level 3: r9720.9=0 and r9720.10=1
Level 4: r9720.9=1 and r9720.10=1
Indicates which parameterized velocity level is currently selected.
Velocity level active
Level 1: r9722.9=0 and r9722.10=0
Level 2: r9722.9=1 and r9722.10=0
Level 3: r9722.9=0 and r9722.10=1
Level 4: r9722.9=1 and r9722.10=1
If one of the velocity levels is currently active, then this is displayed in the
corresponding column.
Active SLS limit value
r9714.0
Displays the load-side velocity actual value of the CU.
The display is updated in the safety monitoring cycle clock.
Commissioning and configuring
6.6 Configuring safety functions integrated in the drive
Safety Integrated (with SINAMICS S120)
Commissioning Manual, 02/2020, A5E46305916B AB
283