05.91
20 Error List with System Stop
Accu1
(FB No.)
Accu2
(E No.)
Error locat.
Error description
65
1
Transfer flag to flag stack
Stack point overflow on flag entry
66
1
Flag stack to transfer flag
Stack point overflow on flag removal
67
1
2
Transfer machine control panel signals > DB axes
"Signals from/to axis" PLC machine data not set
Axis number > 24
68
1
Aperiodic program call
Tool parameter is less than 0
69
1
2
3
G decoding
Channel number inadmissible
Incorrect G group
PLC MD signals from/to NC channel or signals from NC
channel not set
70/71
1
2
3
4
5
6
7
Transfer interface DB to I/Q/F (FB 70) or transfer I/Q/F to
interface DB (FB 71)
Incorrect source or destination type (inadmissible
ASCII character)
Source DB not in programmable controller
Non-compliance with parameter limits
Source or destination DB too short
Parameter limit of flag area exceeded
(No. of DWs too great)
Limit of input or output process image exceeded
Source or destination parameter type inadmissible
(not I/Q/F)
72
1
Transfer NC channel to DB channel-specific signals
Channel address inadmissible
73
1
Transfer DB channel-specific signals to NC channel
Channel address inadmissible
74
1
Transfer spindle to DB spindle-specific signals
Spindle address inadmissible
75
1
Transfer DB spindle-specific signals to spindle
Spindle address inadmissible
76
1
Transfer axis to DB axis-specific signals
Axis address inadmissible
77
1
Transfer DB axis-specific signals to axis
Axis address inadmissible
©
Siemens AG 1991 All Rights Reserved 6ZB5 410-0HE02
20–3