05.91
14 Command Channel (DB 41)
14.6.2 Errors with function 2, "division increment"
14.6.2 Errors with function 2, "division increment"
Error
number
Error meaning
100
(64
H
)
Axis number not allowed for this
mode group or NC channel
101
(65
H
)
Incorrect mode
102
(66
H
)
Channel already assigned
103
(67
H
)
No NC stop state
(safety function for AUTOMATIC)
104
(68
H
)
No NC stop or no read-in enable
(without safety function for AUTOMATIC)
105
(69
H
)
Axis already active in another channel
106
(6A
H
)
User data length not equal to 5
107
(6B
H
)
Impermissible user data
108
(6C
H
)
Option not available
109
(6D
H
)
Incorrect division increment, i.e. division increment > number of divisions
(G90), division number too great with rotary axes, C axis is not indexing
axis (G91)
110
(6E
H
)
Block search active
200
(C8
H
)
Abort by: Reset, mode change, emergency stop, warm restart, servo
disable, NC alarms, follow-up mode, parking axis, coupled motion, transmit,
position behind software limit switch, etc.
© Siemens AG 1991 All Rights Reserved 6ZB5 410-0HE02
14–35
SINUMERIK 880 (PJ)