3. Release the temperature sensor input X200 of the SME125.
4. Release the protective conductor connection of the SME125.
5. Remove the defective SME125 module.
Installing
Procedure:
1. Now install the new SME125 module.
2. Screw on the protective conductor connection.
3. Reconnect the temperature sensor at X200.
4. Reconnect the encoder connecting cable.
5. Connect the DRIVE-CLiQ cable.
Note
Connections/cables
The maximum DRIVE-CLiQ cable length is 100 m.
The maximum encoder cable length is 3 m.
In order to guarantee the degree of protection, all of the plug connectors must be correctly
screwed and snapped into place.
Service cases - hardware
4.17 Sensor Modules External
Software and hardware
Service Manual, 08/2018, 6FC5397-5DP40-6BA1
219