4.11
Motor Module Booksize Compact format
4.11.1
Motor Module Booksize Compact status displays
Status displays
The Motor Module has the following status displays, which provide information about the
module state:
LED state
Description, cause
Remedy
RDY
DC LINK
OFF
OFF
Electronics power supply is missing or outside permissi‐
ble tolerance range.
–-
Green
---
The component is ready for operation and cyclic DRIVE-
CLiQ communication is taking place.
–-
Orange
The component is ready for operation and cyclic DRIVE-
CLiQ communication is taking place.
The DC link voltage is present.
–-
Red
The component is ready for operation and cyclic DRIVE-
CLiQ communication is taking place.
The DC link voltage is too high.
Check the line supply voltage.
Orange
Orange
DRIVE-CLiQ communication is being established.
–-
Red
--
This component has at least one fault.
Note:
The LED is controlled irrespective of the corresponding
messages being reconfigured.
Remove the fault and ac‐
knowledge
Green / Red
(0.5 Hz)
--
Firmware is being downloaded.
–-
Green / Red
(2 Hz)
--
Firmware download has been completed. Wait for POW‐
ER ON.
Carry out a POWER ON
Green/Orange
or
Red/Orange
--
Component recognition via LED is activated (p0124).
Note:
Both options depend on the LED status when module
recognition is activated via p0124 = 1.
–-
DANGER
Danger to life through electric shock due to the residual charge of the DC link capacitors
Hazardous DC link voltages may be present at any time regardless of the state of the
"DC LINK" LED. The warning information on the components must be carefully observed!
Service cases - hardware
4.11 Motor Module Booksize Compact format
Software and hardware
166