SINAUT MD720-3 in Terminal Mode
SINAUT MD720-3
C79000-G8976-C211
35
AT&D
Set circuit Data Terminal Ready (DTR) function mode
Executive command
Command:
AT&D[<value>]
Response:
OK
Parameter: <value>:
0:
Device ignores status on DTR. <Default>
2:
ON->OFF on DTR: Disconnect call, change to command mode. During state
DTR = OFF is auto-answer off.
Notice:
-
AT&F
Restore manufactory configuration
Executive command
Command:
AT&F
Response:
OK
Parameter: <value>:
0:
Restore parameters to manufactory values
Notice:
Restores the configuration of manufacturer of the following commands: ATE, ATQ, ATV,
ATX, AT&C, AT&D, AT\Q and ATS0.
AT&W
Save stored profile
Executive command
Command:
AT&W<n>
Response: OK
Parameter: <n>:
None
Saving in Profile 0
0
Saving in Profile 0
Notice:
This command saves the current configuration in a non volatile memory of the commands
ATE, ATQ, ATV, ATX, AT&C, AT&D, AT\Q and ATS0. The configuration can be reloaded
with ATZ. Before the first saving the profile is the same as the default configuration.
See also AT&V.
AT&V
Display current configuration
Executive command
Command:
AT&V[<value>]
Response: ACTIVE
PROFILE:
<current configuration>
OK
Parameter: <value>:
0:
only active profile
Notice:
The configuration is a text string on multiple lines as shown in the example below. As it is
dependant on the manufactory and user set-up, it is impossible to list the exact number of
information given.
Summary of Contents for SINAUT MD720-3
Page 10: ...Contents SINAUT MD720 3 10 C79000 G8976 C211 ...
Page 22: ...Connecting the device and switching on the device SINAUT MD720 3 22 C79000 G8976 C211 ...
Page 45: ...SINAUT MD720 3 in Terminal Mode SINAUT MD720 3 C79000 G8976 C211 45 ...
Page 74: ...Technical Data SINAUT MD720 3 74 C79000 G8976 C211 ...
Page 76: ...Technical Data SINAUT MD720 3 76 C79000 G8976 C211 ...