Technical data
6.1 Operating modes
TM15 / TM17 High Feature Operating Manual
Commissioning Manual, 05/2009
71
Table 6- 2
Timing for input of measuring input
Timer
TM15
TM17 High Feature
Comments
T1
125 µs
1
1 µs
Resolution
T2
≥ 125 µs
1
≥ 1 µs/125 µs
TM17: Depends on selected
filter times
T3
≥ 125 µs
1
≥ 1 µs/125 µs
TM17: Depends on selected
filter times
T4
Depends on ratio of IPO to servo
T5
Not applicable
(TM15 does not have an
enable function)
≥ 1 µs/125 µs
TM17: Depends on selected
filter times
Times specified for positive logic.
IPO = Interpolator cycle clock
1
DRIVE CLiQ cycle clock, but at least 125 µs
See also
System behavior with binary inputs and outputs (Page 76)
System timing for single measurement (Page 78)
System behavior with cyclic measurement (Page 79)
Configuring I/O channels – TM17 High Feature (Page 25)