Figure 9-8
SIMOTION IT web server
Table 9-14
Functions on the "Diagnostic files" HTML page
Button
Function
Create general diagfiles
This button saves the diagnostic data and non-volatile SIMOTION
data to the ...\USER\SIMOTION\HMI\SYSLOG\DIAG directory.
HTML files used for diagnostics purposes are not saved.
Create html diagfiles
This button is used to save diagnostics HTML pages on the data
carrier. It should be noted that only those pages that are listed in
the DIAGURLS.TXT file in directory ...\USER\SIMOTION\HMI
\SYSLOG\DIAG are backed up, see Section Diagnostics via
Zip all diagfiles
The "zip all Diagfiles" button enables you to compress diagnostics
files. This stores all files and folders in a ZIP file in directory ...
\USER\SIMOTION\HMI\SYSLOG\DIAG, while retaining the fold‐
er structure.
Get diagarchive
This button is used to save the ZIP archive to connected pro‐
gramming devices/PCs.
Delete all diagfiles
This button is used to delete all data stored in the ...\USER\SI‐
MOTION\HMI\SYSLOG\DIAG directory; the directory itself is not
removed, however.
Diagnostics
9.2 Diagnostic data and non-volatile SIMOTION data
SIMOTION D4x5-2
Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B