9.2.3
Diagnostics via websites
In the "DIAGURLS.TXT" text file found in the ...\USER\SIMOTION\HMI\SYSLOG\DIAG
directory, you can specify HTML files whose current content is to be stored on the CF card
when diagnostic data is created during operation (e.g. "devinfo.mwsl" must be entered for the
"devinfo.mwsl" website).
Since the pages in question are stored together with their most up-to-date contents, this
enables the latest status information regarding the SIMOTION device, as well as the machine/
system, from the point at which diagnostic data was created (e.g. when the service selector
switch was activated) to be archived.
In addition to the standard SIMOTION IT web server pages, it is possible to store customized
pages. Information on creating pages of this type can be found in, for example, an FAQ of the
Utilities & Applications.
A tutorial on the creation of user-defined websites is also contained on the Utilities &
Applications-DVD.
Figure 9-6
Diagnostic buffer with generated diagnostic data
The following points must be noted for the DIAGURLS.TXT file:
● A DIAGURLS.TXT file containing the standard websites is automatically created if you have
not stored your own DIAGURLS.TXT file.
● Standard websites are entered "without" specifying a path (e.g. "devinfo.mwsl" for the
standard website "devinfo.mwsl").
● User websites (such as "user.mwsl") in the \USER\SIMOTION\HMI\FILES directory on the
CF card must contain the FILES/ path specification.
Diagnostics
9.2 Diagnostic data and non-volatile SIMOTION data
SIMOTION D4x5-2
Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B