9.1.4
Settings in the Engineering System
1.
Enter IP address of the reader
Enter the assigned IP address in the device settings of the mobile handheld terminal
("RFID devices > RFID device_X").
2.
Enter the network address of the PC
Enter the network address of the PC in the network settings ("Device settings > RFID /
network settings").
Note
An automatic reader search is not possible in the Engineering System
The automatic reader search via "Project > Reader configuration > Communication settings"
does not function in the case of mobile handheld terminals.
9.1.5
Parameterizing the WLAN card in the SIMATIC RF310M mobile handheld
terminal
Two examples are given below for the procedure that you can follow for parameterizing the
WLAN card of SIMATIC RF310M.
Consult your network administrator to ensure that the WLAN connection is set up correctly.
You will find detailed information on configuring the WLAN in the operating instructions for
the PSION WORKABOUT PRO.
Example 1
With this procedure, the active radio networks are displayed automatically.
1.
Set the operating mode to "Supervisor" in SIMATIC RF310M.
2.
In SIMATIC RF310M, select "Start > Programs > Summit > SCU"
3.
Under "Active Config", select "Third party".
4.
To activate these changes, change to the device to the "Powerdown" mode by pressing
the blue <FN> key and the on/off button at the same time for approximately 7 seconds.
The device then restarts.
5.
Select the required active wireless network in the dialog that now opens.
6.
Click the "Connect" button and enter the respective encryption code under
"Authentication" and "Network key".
7.
Click on the "OK" button.