RF-MANAGER RF310M software
9.3 Application mode "Mobile"
SIMATIC RF310M Mobile Reader
66
Operating Instructions, 10/2013, J31069-D0191-U001-A6-7618
Interface structure of the data editor
①
Menu bar
②
Indication of the tag ID
③
Drop-down list box with the transponder-specific memory areas (e.g. USER) that are displayed
in the data field.
④
Length of the data area (the field can be edited if "Complete" is not checked)
⑤
Data field
The data can be displayed in either hexadecimal, decimal or ASCII format.
⑥
Buttons for processing the tag data:
•
Scan tag (ID)
•
Read tag data
•
Write to the tag
⑦
Indication of the tag type: RF300 or ISO
⑧
The editor window contains the tag data. The size of the represented data depends on the tag
type.
⑨
(Start) address (the field can be edited if "Complete" is not checked)
⑩
"Complete" check mark: Indication of the completely selected memory area; all memory areas
of the tag are always read or written at once, independent of the memory area currently set.
⑪
Length of the user area:
The software "RF-MANAGER" contains an additional field for the length of the user area. In this
field, you must enter the tag-specific length of the user area.
One memory area of the most recently scanned tag is always shown in the editor. In the
drop-down list box [
③
], you can select and display the different memory areas of the tag. If
you check "Complete"
⑩
, the current memory area will be displayed complete in the editor,
otherwise you can enter values under "Address" [
⑨
] and "Length" [⑩] to display the
relevant data area only.