Troubleshooting/FAQ
8.5 Configuring the device using the TIA Portal.
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
438
Configuration Manual, 08/2018, C79000-G8976-C267-13
If you now change a parameter directly on the device (WBM/CLI/SNMP) these changes are
lost when the device restarts.
Solution
1.
Open the relevant STEP 7 project in STEP 7 Basic / Professional
2.
Open the project view.
3.
Select the device in the project tree.
4.
Select the "Go to network view" command in the shortcut menu.
5.
Select the device in the network view.
6.
In the shortcut menu of the selected device select the command "SCALANCE
configuration > Save as start configuration".
Result
The configuration is saved on the device. The message is no longer visible in the display
area. A configuration change directly on the device is no longer lost due to a restart of the
device.