Configuring with Web Based Management
6.6 "Interfaces" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
314
Configuration Manual, 08/2018, C79000-G8976-C267-13
CSV file
The CSV file contains information on the configuration of the SCALANCE W700 device and
detailed information on all individual measurements and is divided into two areas. The first
area contains the configured settings:
●
System Name
The system name of the client
●
Device IP
The IP address of the client
●
Device MAC
The MAC address of the client
●
Recording Interval
The interval between acquisition of two measured values
●
Max TX Power
Maximum transmit power of the device
●
Begin Recording
Start of the recording
●
End Recording
End of the recording
●
Recorded Samples
The total number of measurements
●
Max. TX Rate
The maximum data rate of the sent data packets.
●
Max. RX Rate
The maximum data rate of the received data packets.
●
Rx Antenna x type
The setting of the external antennas
The second area is a table. The table contains the following for each measured value:
●
Sample
The current number of the measurement on the client (CL) / on the access point (AP)
●
Timestamp
The time stamp
●
BSSID
The BSSID (Basic Service Set Identification) of the access point
●
CL / AP RX-Signal [%]