PROFINET connection
3.2 Remote service
Cloud Connector
54
Getting Started, 07/2020, C79000-G8976-C507-03
3.2.3
Configuring SINEMA RC and TIA Cloud Connector on the device
Requirement
•
SCALANCE M874 has been created on the SINEMA RC.
•
The SINEMA RC certificate is imported into the SCALANCE M874.
Procedure
1.
Click "System > SINEMA RC" in the navigation area.
2.
Configure the SINEMA RC with the following settings:
SINEMA RC address
IP address of the SINEMA RC server
SINEMA RC port
443
Verification type:
CA certificate
CA certificate
The imported CA certificate
Device ID
The device ID is created automatically when the device is created in the
SINEMA RC server.
Confirm device pass-
word
The password configured for access.
Auto Firewall/NAT
rules
The firewall and NAT rules are created automatically for the VPN connec-
tion. The connections between the configured exported subnets and the
subnets that can be reached via the SINEMA RC server are allowed. The
NAT settings are implemented as configured in the SINEMA RC server.
You can enable SINEMA RC to access specific services of the device under
"Security > Firewall > Predefined IPv4".
Type of connection
Permanent
3.
Select "Enable SINEMA RC" and click the "Set Values" button.
4.
Click "System" > "Cloud Connector" in the navigation area.
5.
Configure the TIA Portal Cloud Connector with the following settings:
Port
9023
(default port)
If you change the default port, make sure that it is not occupied by another ser-
vice.
Protocol
PROFINET
Interface
Activate vlan1 (INT)
6.
Select "Enabled" during operation and click the "Set Values" button.
Summary of Contents for SIMATIC NET SCALANCE M80PB
Page 6: ...Preface Cloud Connector 6 Getting Started 07 2020 C79000 G8976 C507 03 ...
Page 8: ...Table of contents Cloud Connector 8 Getting Started 07 2020 C79000 G8976 C507 03 ...
Page 10: ...Description Cloud Connector 10 Getting Started 07 2020 C79000 G8976 C507 03 ...
Page 38: ......
Page 62: ...Index Cloud Connector 62 Getting Started 07 2020 C79000 G8976 C507 03 ...