PROFIBUS connection
2.1 Local service
Cloud Connector
14
Getting Started, 07/2020, C79000-G8976-C507-03
2.1.2
Enabling the TIA Portal Cloud Connector on the device
Procedure
1.
Click "System" > "Cloud Connector" in the navigation area.
2.
Configure the TIA Portal Cloud Connector with the following settings:
Operation
Enabled
Port
9023
(default port)
If you change the default port, make sure that it is not occupied by another ser-
vice.
Protocol
PROFIBUS
3.
Click the "Set Values" button.
4.
The firewall is enabled on the device by default. Click on "Security" > "Firewall" in the
navigation area and on the "Predefined IPv4 rules" tab in the content area. Enable the pre-
defined "Cloud Connector" IPv4 rule.
5.
Click the "Set Values" button.
Result
The Cloud Connector is started and enabled.