Device maintenance and repair
7.5 Removing and installing hardware
SIMATIC IPC1047
88
Operating Instructions, 09/2018, A5E45118479-AA
Removal
1. Use the LEDs to determine which
module is defective, e.g. the LED
④
lights red.
The LED
①
can also flash red
because there is a warning, e.g.
overload.
2. Alternatively, shut down the device.
Disconnect the power plug
②
from the
power supply module to be replaced.
3. Acknowledge the warning signal on the
LED
④
.
4. Tilt the handle
⑥
forward.
5. Unlock the power supply module at the
pin
③
and pull the module
⑤
straight
forward out of the frame by the handle
⑥
.
6. Slide the new power supply module
into the frame all the way to the rear
until it clicks into place.
7. Reconnect the power plug
②
.
Alternatively, restart the device.
Both LEDs
①
and
④
light in green again.
7.5.4
Replacing the processor
Requirement
●
The device is opened.
●
A suitable processor
Only an approved processor is permitted to be installed on the motherboard of the
device. If the processor type is changed, the BIOS must be updated so that the suitable
microcode is loaded. Information about original spare parts for SIMATIC IPCs is available
on the Internet at:
–
Contacts (
http://www.siemens.com/automation/partner
–
SIMATIC IPC after-sales information system (