User Tasks
2.3 Configuring the WinCC flexible Project
Microbox 427B-RTX/ -HMI/RTX and Panel PC 477B-HMI/ -HMI/RTX
Manual, 12/2007, A5E01217837-01
43
2.3
Configuring the WinCC flexible Project
The Microbox 427B-HMI/RTX and Panel PC 477B-HMI/ -HMI/RTX include WinCC flexible
Runtime (RT) 2007, with the Recipe and Archive options. The license key for the other
WinCC flexible RT options is not included.
You must configure your WinCC flexible project with the WinCC flexible ES (engineering
station) software, and transfer this project from the engineering station computer to WinCC
flexible RT 2007 on the Microbox 427B or Panel PC 477B. WinCC flexible ES is a separate
product and is not included with the Microbox 427B-HMI/RTX or Panel PC 477B-HMI/ -
HMI/RTX.
The runtime configuration file settings for the default administrator user ("Administrator") are
pre-configured to D:\ locations. If you create a new Windows user on the Microbox 427B or
Panel PC 477B, the new user will automatically receive the same runtime configuration file
settings as the default administrator user ("Administrator"). You do not need to change the
runtime settings for the "Administrator" default user or for a new Windows user. For WinCC
flexible RT, a D:\ drive on the CompactFlash card with the Enhanced Write Filter (EWF)
disabled is required.