Operating Instructions
| SICHARGE UC Dispenser UL
Locking
Charging mode 4 for DC charging according to the standard SAEJ1772 requires secure
locking of the
plug-in connection between the charging plug and the charging socket of the vehicle during the entire
charging process. An electromechanical actuator automatically locks the plug-in connection in the electric
vehicle after plugging in.
Temperature monitoring
The integrated temperature monitoring of the charging cable ensures the safe transfer of the
charging power.
Temperature sensors monitor the charging contacts DC+ and DC- during the entire charging process. When
the temperature at one of the charging contacts exceeds 86 °C / 188 °F, the charge controller reduces the
maximum output current. When the temperature
at one of the charging contacts exceeds 90 °C / 194 °F,
the charge controller immediately switches off the power supply of the charging cable.
Performance features
The table below shows the performance features of the two charging cable variants with a
charging plug:
Feature
Value
Charging standard
SAEJ1772
Charging mode
4
Rated current
200 A
Rated voltage
1,000 V DC
Cable outer diameter
1.45” +/-.020”
Power contacts
DC+, DC-, PE
Degree of protection with an inserted charging plug
NEMA 3R
Degree of protection with a charging plug not inserted NEMA 1
27