Connecting the Ethernet cable
Observe the specifications for the routing of Ethernet cables in the section Location planning (Page 33).
1. Insert the Ethernet cable into the SICHARGE UC dispenser to the right of the DC cables.
2. Insert the RJ45 plug of the Ethernet cable into a free connection of the SICHRAGE UC
dispenser Ethernet switch -A2.
Note
Assembling
the
industrial
Ethernet
connector
Follow the instructions of the connector manufacturer to assemble the industrial Ethernet connector.
Cable routing considerations
All circuits (incoming AC power wiring, DC wiring to dispensers, and communications wiring) should
be ran in separate conduit runs until reaching the cable gland plates.
Fastening the cable
Secure the Ethernet cable after the connection to the cable duct.
Connection of additional SICHARGE UC dispensers
The Ethernet connection is looped through to connect additional SICHARGE UC dispensers to
the same
SICHARGE UC charging station. This is shown as item
s
in the “Ethernet connection” figure. To do this,
perform the sequence shown above to connect the Ethernet cable.
NOTICE
Network connection
The SICHARGE UC devices form a closed network.
Do not establish a connection to other networks and devices.