SICHARGE UC Dispenser UL |
Operating Instructions
Charging contacts
To safely transmit the high charging power, the Tap 1 connector of the charging cable uses the following charging contacts:
Figure 3-2 Charging contacts
No.
Contact
Use
a
AC Power (L1)
Single-phase AC contact or DC+ when using Level 1 power
s
Control Status (CS)
The PD contact enables the vehicle to detect the presence of a
charging plug.
d
Protective Earth (PE)
The PE grounding contact protects the device in case of a
faulty cable connection.
f
Direct Current Plus (DC+)
The DC+ contact forms the plus pole for direct current
charging.
g
Direct Current Minus (DC-)
The DC- contact forms the negative pole for DC charging.
h
Control Pilot (CP)
Vehicle and charging station communicate via the signal
contact CP.
j
AC Power (L2, N)
AC neutral contact or DC- when using Level 1 power
26