SICHARGE UC Dispenser UL |
Operating Instructions
6.3 Connecting the DC cable
To connect the SICHARGE UC dispenser to the SICHARGE UC charging station, connect the DC
cable to the DC connectors of the SICHARGE UC dispenser.
Requirements
•
You
have
opened
the
cabinet.
• You have removed the protective cover on the left.
• You have inserted the DC cable into the cabinet.
Connections for the DC cable
The following figure shows the connection of the DC cable.
a
DC+ conductor
s
DC- conductor
d
PE conductor
f
Loop through for daisy chain
(DC+, DC-, PE) shown as
dashed lines
Figure 6-2 DC cable connection
56