9.2
XR-300M EEC mechanical stability (in operation)
The devices of the SCALANCE XR-300M EEC product group meet the following standards
(prerequisite: rack mounted with 4 securing points):
● IEC 60068-2-6
(vibrations during transportation and operation)
Test parameters:
5 – 9 Hz: 3.5 mm
9 – 150 Hz: 1 g
1 octave/min, 20 sweeps
● IEC 60068-2-27
(shocks during operation)
Test parameters:
15 g, 11 ms duration
6 shocks per axis
● IEC 60068-2-6
(vibrations during transportation)
Test parameters:
10 – 58 Hz: 0.075 mm
85 – 150 Hz: 1 g
1 octave/min, 20 sweeps
Installation guidelines
The devices meet the requirements if you adhere to the installation and safety instructions
contained in this documentation and in the following documentation when installing and
operating the devices.
● "Industrial Ethernet / PROFINET Industrial Ethernet" System Manual (
support.industry.siemens.com/cs/ww/en/view/27069465
● "Industrial Ethernet / PROFINET - Passive Network Components" System Manual (
support.industry.siemens.com/cs/ww/en/view/84922825
● "EMC Installation Guidelines" configuration manual (
https://support.industry.siemens.com/
)
WARNING
Personal injury and property damage can occur
The installation of expansions that are not approved for SIMATIC NET products or their target
systems may violate the requirements and regulations for safety and electromagnetic
compatibility.
Only use expansions that are approved for the system.
Approvals
9.2 XR-300M EEC mechanical stability (in operation)
SCALANCE XR-300M EEC
78
Compact Operating Instructions, 11/2019, A5E02661176-14
Summary of Contents for SCALANCE XR324-4M EEC
Page 10: ...Introduction SCALANCE XR 300M EEC 10 Compact Operating Instructions 11 2019 A5E02661176 14 ...
Page 12: ...Safety notes SCALANCE XR 300M EEC 12 Compact Operating Instructions 11 2019 A5E02661176 14 ...
Page 84: ...Index SCALANCE XR 300M EEC 84 Compact Operating Instructions 11 2019 A5E02661176 14 ...