RUGGEDCOM M2200
Installation Guide
Chapter 5
Technical Specifications
Fiber Optic Ethernet Port Specifications
27
Connector
micro-D
Speed
1000 Mbps
Duplex
e
FDX/HDX
Cable Type
f
> CAT-5
Wiring Standard
g
TIA/EIA T568A/B
Maximum Distance
h
100 m (328 ft)
Isolation
i
1.5 kV
e
Auto-Negotiating
f
Shielded or unshielded.
g
Auto-crossover and auto-polarity.
h
Typical distance. Dependent on the number of connectors and splices.
i
RMS 1 minute.
Section 5.5
Fiber Optic Ethernet Port Specifications
The following details the specifications for fiber Ethernet ports that can be ordered with the RUGGEDCOM M2200.
Gigabit Ethernet (1 Gbps) Optical Specifications
NOTE
These transceivers utilize a distributed feedback (DFB) type laser and are rated for -20 to 85 °C (-4 to
185 °F) operation only.
Tx (dBm)
l
Mode
Connector
Type
Cable
Type (µm)
j
Tx λ (nm)
k
Minimum
Maximum
Rx
Sensitivity
(dBm)
l
Rx
Saturation
(dBm)
l
Distance
(km)
m
Power
Budget
(dB)
MM
LC
50/125
850
-9
-2.5
-20
0
0.5
11
MM
LC
62.5/125
850
-9
-2.5
-20
0
0.5
11
SM
LC
9/125
1310
-9.5
-3
-21
-3
10
11.5
SM
LC
9/125
1310
-7
-3
-24
-3
25
17
j
All cabling is duplex type unless specified otherwise.
k
Typical.
l
All optical power numbers are listed as dBm averages.
m
Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens
sales associates when determining maximum segment distances.
Summary of Contents for RUGGEDCOM M2200
Page 4: ...RUGGEDCOM M2200 Installation Guide iv ...
Page 10: ...Preface RUGGEDCOM M2200 Installation Guide x Customer Support ...
Page 16: ...Chapter 1 Introduction RUGGEDCOM M2200 Installation Guide 6 Supported Fiber Optic Cables ...
Page 28: ...Chapter 2 Installing Device RUGGEDCOM M2200 Installation Guide 18 Wiring Examples ...
Page 42: ...Chapter 5 Technical Specifications RUGGEDCOM M2200 Installation Guide 32 Dimension Drawings ...