background image

http://www.3com.com/

Router 6000 and 3000 DSL 
Family Release Notes

Software V 2.01

Router 6040 (3C13840)
Router 6080 (3C13880)
Router 3030 (3C13630)
Router 3031 (3C13631)
Router 3032 (3C13632)
Router 3033 (3C13633)
Router 3034 (3C13634)
Router 3035 (3C13635)

Part No. 10014363
Published August 2004

Summary of Contents for Router 3030

Page 1: ... DSL Family Release Notes Software V 2 01 Router 6040 3C13840 Router 6080 3C13880 Router 3030 3C13630 Router 3031 3C13631 Router 3032 3C13632 Router 3033 3C13633 Router 3034 3C13634 Router 3035 3C13635 Part No 10014363 Published August 2004 ...

Page 2: ......

Page 3: ...ase verify the software version running on your router You can verify the software version by issuing a display version command on your router If the display output shows 3Com Router Software V2 00 please upgrade your router software to version 2 01 You can obtain the latest version of router software from the 3Com support web site IMPORTANT For 3Com Router 3000 DSL Family running V2 00 router sof...

Page 4: ...11 cable is provided for an external splitter with RJ 11 connection This cable can also be used for RJ 45 connection if the external device has this type of interface available only System Access Issuing the display current configuration command on the Router 3000 DSL Family will result in some packet loss during heavy traffic times Please refrain from issuing the current configuration command dur...

Page 5: ... Dialer interface statistics are NOT accurate for flow intervals under 300 seconds For flow intervals between 10 and 300 seconds check the associated physical interface for accurate statistics The Router 3000 DSL Family Ethernet interface displays physical and protocol states as up up even when there is no cable connection The interface responds to pings even with no cable connection The Router 30...

Page 6: ...route dampening does not work for IBGP routes BGP dampening works for EBGP routes only Multicast Protocol The default value for the IGMP query interval does not match the recommended value in RFC 2236 Set the query interval to match the query interval of other routers in your network PIM is not supported with IP unnumbered FR interfaces An IP address must be assigned to the FR interface Security N...

Page 7: ...type is wide its range is 0 to 16777215 The Router 6000 Family uses the frame relay terminology Cir Allow and Cir instead of Cir and MinCir respectively Please refer to the following documents 3Com Router Command Reference Manual page 1033 3Com Router Configuration Guide page 1019 Text Correction Use CIR Allow when configuring the maximum Committed Information Rate for the DTE when no network cong...

Page 8: ...ng scheme is different from that documented The following is the corrected numbering scheme 1000 1099 Interface based ACL 2000 2099 Basic ACL 3000 3099 Advanced ACL 4000 4999 Ethernet Frame Header ACL The Command Reference Manual states that reset ike sa will clear both phase 1 and phase 2 security associations reset ike sa will only clear phase 1 security associations reset ipsec sa will clear ph...

Reviews: