38
4.9
HOW TO CHECK A PROGRAMME
Cycles Menu
Program edit
: (1)
Loop table
: (2)
Save program
: (3)
Load program
: (4)
Delete program
: (5)
Ripetition
: (6)
Ver. curr. progr.
: (7)
Choice
7
Start progr.
STOP
Monitoring
: OFF
to visualize the current programme data
VER. CURRENT PROGRAM
< ESC > Prev. menu
Segment N
°
_ _ _
Load segment
LOAD
T2
T3
T4
T1
T5
ESC
Digit which segment you wish to visual-
ize
To load and visualize the segment
OP7
RAM work memory
SIEMENS
SIMATIC OP7
F1
F2
F3
F4
K1
K2
K3
K4
7
8
9
4
5
6
1
2
3
.
0 +/-
SHIFT
INS
DEL
HELP
ENTER
ACX
ESC
MICRO
PLC
To visualize all the options for the selected
segment
This option enables one or more segments of the
programme being loaded into the memory to be
checked.
The data in the memory cannot be modified at this
stage.
The following will appear
Press several times
Summary of Contents for OP7
Page 3: ......