SIMOLINK drive coupling
5-14
Function Blocks - FM 458-1 DP
Edition 12.2004
TAD
Hardware address SLB (name of the SLB module), which can be
configured in HWConfig
FSL
Address of the first slave to which setpoint XS0 should be sent,
value range 1 . . . 200
(initialization connection)
(default: 1)
NSL
Number of slaves to which the setpoint should be sent,
value range 1. . . 8
(initialization connection)
(default: 1)
CSV
Number of the channel on which the setpoint is sent,
value range 0 . . . 7
(initialization connection)
(default: 0)
XS0
to
XS7
Setpoint XS for slaves 1 to 8,
A maximum of 8 setpoints can be sent.
(default: 0)
SEQ
Sequence number
Number of the blocks in the SIMOLINK block sequence
This value provides information as to whether the block was correctly
initialized.
(default: 0)
YF
Error status of the block
YF=0
no error, YF > refer to coded error output @SL
(default: 0)
QF
Group error bit
QF=0 no error, QF=1 for error (if YF
≠
0)
(default: 0)
Computation time [µs]
FM 458-1 DP
34,7
Can be inserted online
No
Can be configured in
Interrupt tasks
Cyclic tasks
Executed in
Initialization mode
Normal mode
Special features
-
I/O
Configuringdata