Communication blocks
Function Blocks - FM 458-1 DP
2-19
Edition 12.2004
QF
Error status block
QF=1: There is an error; for details, refer to YF
0.0
YF
StatusInfo Block
§§ as for the DRD block!
16#0000
Computation time [µs]
FM 458-1 DP
5,0 + 0.7 for each byte
Can be inserted online
Yes
Can be configured in
Interrupt tasks
Cyclic tasks
Executed in
Initialization mode
Normal mode
Special features
The block must be configured in the
same
sampling time
as the blocks, connected via the pointer interface
(CFC connection via connections PTR).
This can only be used for the FM 458-1 DP!
Several S7WR_P blocks can be configured.
Although this is not a typical application, it can
make sense if, for example, the 128 byte area
should be written in several blocks or if data is
required in different sampling times.
Configuring data