40
FLUDEX 4612 en
Operating instructions 10/2017
9.2
Possible faults
Table 7:
Possible faults
Faults
Possible causes
Remedy
Sudden changes in the noise
level and/or sudden vibrations.
Change in alignment.
Flexible elements (12) worn.
Stop the installation.
If necessary, rectify any cause of the
changes in alignment (e.g. by fastening
loose foundation bolts).
Check and, if necessary,
adjust alignment; see section 6.
Check wear; procedure as described
in section 10.
Stop the installation.
Demount coupling and remove
remains of flexible elements (12).
Check and replace damaged
coupling parts.
Flexible elements (12) must be
changed in sets; use only identical
NEUPEX flexible elements (12).
Fitting of coupling according
to section 6 and section 7.
No torque transmission.
The fusible safety plugs have
fused through overheating or
locking and the fluid is escaping
from the coupling.
Stop the installation.
Rectify the cause of the overheating
or locking.
Change all fusible safety plugs
as well as the operating fluid.
Refill the coupling
as described in section 7.