48
FLUDEX 4612 en
Operating instructions 10/2017
13
10
3
23
1)
Fig. 14:
Removing the FLUDEX coupling a
1) Mark
The axial space thus obtained is sufficient to detach the main coupling axially from the hubcarrier
part (120) and demount it radially after the bolts (139) have been loosened. At the same time care must
be taken that the Orings (117, 138) are exposed (see figure 15).
1)
2)
120 139 117 138
Fig. 15:
Removing the FLUDEX coupling b
1) Orings
2) Main coupling
WARNING
Serious injury
Risk of serious injury through incorrect handling of the device and pump when demounting press fits.
Observe manufacturer's instructions for using the forcingoff / detaching device and pumps.
Summary of Contents for FLENDER FLUDEX FNA