SINAMICS V60 Controlled Power Module (CPM60.1) Getting Started EN-15
Installation
SIMATIC PLC/SINAMICS V60 signal cable
It is recommended to use SIEMENS-designed SIMATIC PLC/SINAMICS V60 signal cable (length: 3m) to
connect SIMATIC PLC and SINAMICS V60. This signal cable can be ordered with MLFB of 6ES7298-2DS23-
0XA0.
PE
PE
M
M
3M
3L+
L+
L+
1M
I0.0
Q0.0 Q0.1
Q0.2 Q0.3
Q0.4
Q0.5 Q0.6
I0.1
I0.2
DC 24 V
PULS
DIR
ENA
RST
CPU 1214C
DC / DC / DC
ALM
RDY
Z-M
P24V/M
M
P24V
If SIMATIC PLC is S7-1200 series, please see the following wiring diagram (example):
(orange)
(blue)
(brown)
(white)
(yellow)
(gray)
(purple)
(red)
(black)
(white)
(red+white)
PULS1 (orange)
RST (white)
M24 (black)
PULS2 ( white)
DIR1 (blue)
ENA1 (brown)
ALM1 (purple)
RDY1 (gray)
RDY2 (red + white)
+24V (red)
Z-M (green)
Z-M24 (green + white)
ALM1 ( white)
ENA2 (brown + white)
DIR2 (blue + white)
The CPM60.1 drive unit should be connected to an external 24 V DC power supply (rated input current 2 A),
which enables the drive to normally work under the voltage range of 24 V (- 15% to +20%). Since the excellent
quality of a DC power supply is critical to the stable operation of a drive system, Siemens recommends you to
select a SIEMENS DC 24 V stabilized power supply (order number: 6EP1333-3BA00). If there is no SIEMENS
DC 24 V power supply available, you can use a non-SIEMENS high-quality power supply instead.
External 24 V DC Power Supply
Filter
Circuit breaker
A line filter (rated current 16 A, protection level IP20) is required so that the system can pass the CE certification
(radiated emission test or conducted emission test). The filter recommended by SIEMENS has an order number
of 6SN1111-0AA01-1BA1.
You can install a mains linear breaker (rated current: 15 A for 7 A or 10 A version of the drive and 10 A for 4 A
or 6 A version of the drive; rated voltage: 250 VAC) to protect the system.
NOTE
As 65 signal from SINAMICS V60 drive is recommended for emergency stop, it is not used in SIMATIC
PLC/SINAMICS V60 signal cable.
For a SIMATIC PLC (S7-1200 series), signal PULS can only be connected to output terminal Q0.0 or
Q0.2, and terminal Q0.1 or Q0.3 is used for direction output.